Sistema solar para fábrica

Complete package includes: high-efficiency solar panels, durable solar brackets, long-cycle solar batteries (6,000+ charge-discharge cycles at 80% DoD), solar inverter with MPPT controller (conversion efficiency ≥95%), high-temperature resistant cables, and MC4 connectors.

Nuestro sistema solar de gran éxito para fábricas abarca desde 100 kW hasta 2 MW, con salida de voltaje amplio de CC 110 V/220 V/380 V a CA 110 V~480 V, ideal para fábricas y plantas de fabricación de tamaño mediano a grande. Totalmente personalizable según las necesidades energéticas de su fábrica (capacidad, voltaje, diseño de instalación).

For a real-world reference, see how we engineered a solar system for an electroplating factory — 2 MW, $26,500/month savings, 11-month payback.

Especificación del producto

Modelo:
Sistema solar MS para fábrica
Tipo:
Solución de fábrica
Voltaje de salida:
CC: 110V/220V/380V 
CA: 110V~480V
Compartir como:

Presentación de videos

Ventajas

Soluciones solares completas incluyendo todos los componentes.
Volumen reducido, alta densidad energética, ahorrando 40% de espacio de instalación en comparación con las baterías de gel.
Factory-direct industrial supply with no distributor margin; systems certified to CE, RoHS and TUV.
Cómodo mantenimiento posventa: paneles solares, baterías, inversor solar con controlador mppt. Todas las tareas a una sola empresa.
Celda de batería completamente nueva de grado A++. Certificaciones: SGS, CE, ROHS, TUV.
Hybrid inverter and LiFePO4 storage supplied as one matched system, 6,000+ cycles at 80% DoD.
Fast charge-discharge speed, adaptive to the MPPT controller’s charging mode. Low self-discharge rate (≤1% per month), long cycle life (6,000+ charge-discharge cycles at 80% DoD)

Parámetros

MOQ: 1 juego, aceptamos OEM y ODM

Certificado: TUV, ETL, ISO, CE, RoHS

Pago: T/T, L/C, Paypal, Western Union

Lista de equipos del sistema

Solar PV modules for cold storage solar power system supply
Panel solar
1. Utilizando una celda solar tipo N 16-18BB, la eficiencia de generación de energía es 25.5%
2. Mediante un proceso de corte totalmente automático, 100% garantiza que no haya espacios en la célula solar.
3. Control de calidad: Clasificación de la eficiencia celular/potencia celular
4. Prueba EL 4 veces
5. Se adopta el proceso automático de soldadura por confluencia de celdas para garantizar que no haya soldaduras falsas.
6. Proceso de llenado de pegamento totalmente automático para garantizar la vida útil de los paneles solares hasta 30 años.
7. Embalado en cajas de madera para garantizar la entrega segura de las mercancías.
Hybrid solar inverter for cold storage solar power system
Inversor híbrido dentro y fuera de la red
1. Función perfecta: lleva la energía a la red, cargador de red de CA integrado.
2. Funciones de protección: Protección contra sobrecarga, cortocircuito, sobrecalentamiento,
3. Eficiencia antiisla aislada, polaridad inversa, 5 años de garantía
Rack-mounted lithium battery cabinet for cold storage backup power
Batería de litio nueva y duradera (LiFePO4)

1. Tecnología alemana, incluido BMS, 10 años de garantía.
2. Celdas de batería nuevas, capacidad genuina 100% garantizada.
3.Vida útil: 16-20 años

What a Solar System for Factory Must Deliver

A sistema solar para una fábrica has to do more than cut an electricity bill - it must protect production. Motor starts, welding sets, compressors and CNC lines create surge loads and power-quality events that a domestic system cannot absorb. A sistema solar para una fábrica is designed around the load profile of the plant, not around a nameplate rating.

In Nigeria, Ghana and Kenya, where grid interruptions stop a shift mid-run, the storage component matters as much as the PV array. Our sistema solar de una fábrica de galvanoplastia case explains how that is engineered.

Sizing PV and Storage for Industrial Loads

We start with 7 to 14 days of logged consumption, split base load from shift peaks, and size the PV array on daytime energy while sizing the battery on the evening block. A plant consuming 900kWh a day with a 400kWh daytime share needs roughly 100kWp of PV plus a storage bank covering the remaining 500kWh.

Inverter selection follows the surge profile. Three-phase machinery with 3x inrush needs a bidirectional inverter rated for that surge, which is why we specify an Sistema de almacenamiento de energía en batería (BESS) de 125 kW rather than stacking single-phase units.

Send the motor list and twelve months of bills, and your sistema solar para una fábrica proposal comes back with a sized PV array, inverter rating and battery capacity.

What a Solar System for Factory Includes

A complete sistema solar para una fábrica from Mars Solar includes PV modules, mounting structure, DC and AC protection, hybrid or bidirectional inverters, LiFePO4 storage, cable, MC4 connectors and a monitoring gateway. Everything is matched and factory-tested as one system.

Storage modules are rack-mounted for serviceability, as shown on our batería de almacenamiento de energía montada en bastidor page. For plants with a heavy overnight load, see the Caso práctico de una instalación solar industrial de 2 MW.

A sistema solar para una fábrica rooftops and yards is only as good as the load data behind it; every sistema solar para una fábrica we ship is sized from logged consumption, not from a template.

Buying a Solar System for Factory Direct

Mars Solar exports industrial systems directly, so a sistema solar para una fábrica is priced at factory level without distributor margin. Systems are certified to CE, RoHS, TUV and ISO standards, with a 10-year battery warranty and 5-year inverter warranty.

Model the investment with our storage cost guide, and see commissioning practice in our Sudan microgrid build.

Industrial energy is the largest single category of global demand. The U.S. Department of Energy's Oficina de Tecnologías de Energía Solar explains how on-site generation cuts both cost and carbon for manufacturing - a solar system for factory is a cost-reduction measure before it is an environmental one.

Preguntas frecuentes

How is a solar system for factory sized?

We start with 7 to 14 days of logged consumption, split base load from shift peaks, and size the PV array on daytime energy while sizing the battery on the evening block. A plant consuming 900kWh a day with a 400kWh daytime share needs roughly 100kWp of PV plus a storage bank covering the remaining 500kWh.

What should buyers check before ordering a solar system for factory?

Mars Solar exports industrial systems directly, so a solar system for factory is priced at factory level without distributor margin. Systems are certified to CE, RoHS, TUV and ISO standards, with a 10-year battery warranty and 5-year inverter warranty.

A Day on Site: Factory Load and System Operation

Worked example for sizing discussion, not a project measurement. A plant consuming about 900 kWh a day with a 400 kWh daytime share, served by 100 kWp of PV (about 450 kWh a day) and a storage bank carrying the remaining 500 kWh outside the solar window.

TimeMain loadsAverage kWkWh in blockSupply and battery
22:00–06:00Continuous process, finished-goods cold store, security and yard lighting42336Battery carries the whole night block
06:00–08:00Shift start-up: compressors, motor inrush, welding sets30 (about 3× on start)60PV plus battery; the battery absorbs the start-up surge
08:00–12:00Morning shift at full production37150PV direct
12:00–14:00Break and shift handover, base load only2040PV direct; surplus charges the battery
14:00–18:00Second shift at full production38150PV direct; battery covers the difference
18:00–22:00Second-shift tail: finishing lines, packing, yard lighting40160Battery carries the block

Reading the day: about 385 kWh is consumed at the moment it is generated, and roughly 500 kWh falls outside the solar window and is carried by the storage bank, with the grid or a generator as backstop. The 65 kWh of midday surplus is captured rather than exported. The 06:00–08:00 block is the hard one — motor inrush is a power problem measured in kW, not an energy problem measured in kWh, so it sets the inverter rating rather than the battery size.

kW, kWh and What the Battery Actually Covers

kW is power; kWh is energy. Three-phase machinery with 3× inrush current is a kW problem: the bidirectional inverter has to be rated for that surge, which is why we specify a single industrial BESS rather than stacking single-phase units. The 900 kWh the plant uses in a day is a kWh problem: it sets the array size and the storage bank. Adding motor nameplate ratings together answers neither question.

Whole-site backup versus critical-load backup. Whole-site backup keeps every line running through an outage and needs a battery sized to full-shift power — typically two to three times the storage cost. Critical-load backup keeps only the line that cannot stop: the continuous process, the cold store, control and safety systems, and lighting. The deciding input is permitted downtime. A plant that can ride through 20 minutes needs far less battery than one that cannot lose a second, and that answer belongs in the specification before anyone prices the storage.

What We Need From You to Size a Factory System

Shift load — how many shifts, and the kW and kWh of each. Three-phase motor list — rating, quantity and starting method: direct-on-line, star-delta or variable-frequency drive. Critical production line — which line cannot stop, and what it draws. Permitted downtime — seconds, minutes, or until the end of the shift. Expansion allowance — whether a line is added in the next two to three years, so inverter and distribution capacity are reserved now. Roof condition — structure, orientation, usable area, and any corrosion, dust or heat that the equipment has to live with. We start from 7–14 days of logged consumption and split base load from shift peaks before anything is specified.

Descargue nuestro folleto de productos para obtener más detalles.
Descargar PDF
Descargue nuestro folleto de productos para obtener más detalles.
Solicitar una cotización